· Product launches· 日本語で読む
HumansX Opens Second Reservation Period for Wuji Hand 2, Proposes Bimanual Data Collection System
HumansX has opened reservations for the second batch of its 20-degree-of-freedom robotic hand, the Wuji Hand 2. It also proposes a bimanual data collection system paired with the Wuji Glove data glove. The second batch is scheduled for delivery in order of reservation from February 2027, with the Marvin Pro as the selected arm.
Key facts
- HumansX has opened reservations for the second batch of the Wuji Hand 2, with deliveries scheduled to begin in order of reservation from February 2027.
- The Wuji Hand 2 has four degrees of freedom per finger, for a total of 20, and supports 1000Hz×20-axis control.
- The Wuji Glove has 526 tactile sensors and measures at 120FPS.
- The bimanual data collection system has Wuji Hand 2 units on both arms, and the selected arm is the Marvin Pro.
- HumansX said the first batch’s reservation slots filled within three weeks of opening.
What happened
In an official announcement dated Nov. 6, 2026, HumansX opened reservations for the second batch of its 20-degree-of-freedom robotic hand, the Wuji Hand 2. The first batch’s reservation slots filled within three weeks of opening, and the second batch is scheduled for delivery in order of reservation from February 2027. RoboSuta reported Nov. 9 that the company also proposed a data collection system with the hand and Wuji Glove tactile data gloves mounted on both arms. The selected arm is the Marvin Pro.
Why it matters
HumansX proposes combining the Wuji Hand 2 and Wuji Glove in a bimanual system for teleoperation and data collection for imitation learning and VLA. Offering a complete setup, rather than only the hand, is relevant to research and development teams that face challenges in configuring and launching equipment to begin collecting operation data at work sites.
Analysis
The key point is not only that reservations have opened for the robotic hand, but also that HumansX is proposing a setup for mapping an operator’s hand movements to a robot and collecting data at work sites. The Wuji Hand 2 has 20 active degrees of freedom, while the Wuji Glove measures hand movements and tactile information. Combining the two on a bimanual arm setup broadens the offering from sales of the hand alone to a system proposal for starting teleoperation and data collection. However, the announcement does not specify the format of the collected data or how readily it can be reused across different robots.
The proposed workflow is to capture human hand movements and tactile information, remotely operate the robotic hands, record real tasks, and use the data for imitation learning or VLA. HumansX cites installation at work sites and the ability to begin collecting data immediately after delivery as features of its proposal. Collecting data in the field, rather than only in a lab, could provide access to data from different environments and working conditions. However, the company has not disclosed operating hours, data volumes or task reproducibility after installation, so operational results will be needed to assess the system’s practicality.
A Nov. 5, 2026, article, Panasonic HD and Partners Develop T-Rex Robot Operation AI, With 65% Average Success Rate Across 12 Tasks, covered AI development using robot operation data that included tactile information. HumansX’s proposal is not an announcement of AI model performance; it focuses on equipment and an operating environment for collecting hand movements and tactile data. Data synchronization, labeling and post-training motion evaluation would be key to linking the two, but no specifics on these areas have been disclosed.
A separate article published Nov. 9, 2026, Robot Bank Steps Up Development of Physical AI Robots Under Its Own Brand, Starting With a Quadruped, reported the company’s plans to develop robots under its own brand, with specifications and mass-production timing to be determined based on further development and testing. In contrast, HumansX’s announcement details a data acquisition environment combining an existing hand, glove and arm. Robot development and data collection equipment are efforts at different stages, and no information indicates that they are in direct competition.
The first batch’s reservation slots filling up indicates demand, but HumansX has not disclosed the number of reservations or production slots, so the figure does not provide a basis for assessing production scale. The next details to watch are the number of units and pricing for the second batch, delivery schedules for different bimanual system configurations, specifications for data collected at work sites, and the results of training and evaluation using that data.
Details
The Wuji Hand 2 is a five-finger hand with four degrees of freedom per finger, for a total of 20, all actively driven using a direct-drive system. Its joints are backdrivable, with less than 1° of backlash. It supports 1000Hz×20-axis control and MIT force-position hybrid control, has peak fingertip force of at least 12N and opens and closes at least four times per second. It measures approximately 180×80×40mm, weighs about 800g, and supports Python/C SDK and ROS 2.
The Wuji Glove has 526 tactile sensors across the entire palm and measures hand movements and tactile information at 120FPS. Its electromagnetic six-degree-of-freedom tracking provides fingertip position accuracy of within 2mm RMS; wired latency is no more than 10ms, and the glove weighs 67.5g. The bimanual system has Wuji Hand 2 units on both arms and uses the glove to reproduce the operator’s hand movements. Setup and adjustment are included. Pricing is available on request, and system delivery times vary by configuration.
Sources
Translated from the Japanese original: /news/humansx-20-jiyuudo-robottohando-wuji-hand-2-no-dai-2-ki-yoya-dc832b. The Japanese version is authoritative if they differ.