2段階キャリブレーションによるケーブル駆動手術ロボットの高速・高信頼な自律デブリードマン
Fast and Reliable Autonomous Surgical Debridement with Cable-Driven Robots Using a Two-Phase Calibration Procedure
ケーブル駆動手術ロボットの非線形誤差を、粗調整(DNN)と微調整(ランダムフォレスト)の2段階キャリブレーションで補正し、レーズンやカボチャ種子の除去作業で平均誤差を4.55mmから1.08mmへ低減した。
著者: Daniel Seita, Sanjay Krishnan, Roy Fox, Stephen McKinley, John Canny, Ken Goldberg
分類: cs.RO
原文アブストラクト
Automating precision subtasks such as debridement (removing dead or diseased tissue fragments) with Robotic Surgical Assistants (RSAs) such as the da Vinci Research Kit (dVRK) is challenging due to inherent non-linearities in cable-driven systems. We propose and evaluate a novel two-phase coarse-to-fine calibration method. In Phase I (coarse), we place a red calibration marker on the end effector and let it randomly move through a set of open-loop trajectories to obtain a large sample set of camera pixels and internal robot end-effector configurations. This coarse data is then used to train a Deep Neural Network (DNN) to learn the coarse transformation bias. In Phase II (fine), the bias from Phase I is applied to move the end-effector toward a small set of specific target points on a printed sheet. For each target, a human operator manually adjusts the end-effector position by direct contact (not through teleoperation) and the residual compensation bias is recorded. This fine data is then used to train a Random Forest (RF) to learn the fine transformation bias. Subsequent experiments suggest that without calibration, position errors average 4.55mm. Phase I can reduce average error to 2.14mm and the combination of Phase I and Phase II can reduces average error to 1.08mm. We apply these results to debridement of raisins and pumpkin seeds as fragment phantoms. Using an endoscopic stereo camera with standard edge detection, experiments with 120 trials achieved average success rates of 94.5%, exceeding prior results with much larger fragments (89.4%) and achieving a speedup of 2.1x, decreasing time per fragment from 15.8 seconds to 7.3 seconds. Source code, data, and videos are available at https://sites.google.com/view/calib-icra/.
関連論文
- SurgCalib: ガウススプラッティングに基づくロボット支援低侵襲手術のためのハンドアイキャリブレーション手術ロボット/キャリブレーション
- da Vinci手術ロボットのためのオンザフライハンドアイキャリブレーション手術ロボット/キャリブレーション
- 実環境における手術ロボット器具の姿勢を統合的特徴検出で効率的に再構成手術ロボット/キャリブレーション
- 手術シーンからのオンラインハンドアイ変換推定手術ロボット/キャリブレーション
