日本フィジカルAI新聞

世界のフィジカルAIを、日本語で。

筋電/超音波インタフェースarXiv:1809.01952

超音波筋コンピュータインタフェースにおけるスパース性解析

Sparsity Analysis of a Sonomyographic Muscle-Computer Interface

シェア:XThreadsFacebookLINEはてブBluesky

前腕の最適な超音波プローブ位置を特定し、少数の走査線でも十分な動作分類精度が得られることを示した研究。

著者: Nima Akhlaghi, Ananya Dhawan, Amir A. Khan, Biswarup Mukherjee, Cecile Truong, Siddhartha Sikdar

分類: cs.HC, cs.RO

原文アブストラクト

Objective: The objectives of this paper are to determine the optimal location for ultrasound transducer placement on the anterior forearm for imaging maximum muscle deformations during different hand motions and to investigate the effect of using a sparse set of ultrasound scanlines for motion classification for ultrasound-based muscle computer interfaces (MCIs). Methods: The optimal placement of the ultrasound transducer along the forearm is identified using freehand 3D reconstructions of the muscle thickness during rest and motion completion. From the ultrasound images acquired from the optimally placed transducer, we determine classification accuracy with equally spaced scanlines across the cross-sectional field-of-view (FOV). Furthermore, we investigated the unique contribution of each scanline to class discrimination using Fisher criteria (FC) and mutual information (MI) with respect to motion discriminability. Results: Experiments with 5 able-bodied subjects show that the maximum muscle deformation occurred between 30-50% of the forearm length for multiple degrees-of-freedom. The average classification accuracy was 94.6% with the entire 128 scanline image and 94.5% with 4 equally-spaced scanlines. However, no significant improvement in classification accuracy was observed with optimal scanline selection using FC and MI. Conclusion: For an optimally placed transducer, a small subset of ultrasound scanlines can be used instead of a full imaging array without sacrificing performance in terms of classification accuracy for multiple degrees-of-freedom. Significance: The selection of a small subset of transducer elements can enable the reduction of computation, and simplification of the instrumentation and power consumption of wearable sonomyographic MCIs particularly for rehabilitation and gesture recognition applications.

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  3. 3NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  4. 4GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  5. 5Google DeepMind、ロボット向けAIを発表新製品・発表

PR・アフィリエイト広告

MINISFORUM(ミニPC)

MINISFORUM(ミニPC)の公式広告バナーMINISFORUM公式ストアを見る ↗
PR本紙発行元 EmplifAI