日本フィジカルAI新聞

世界のフィジカルAIを、日本語で。

キャリブレーションarXiv:2005.08420

単眼視と非線形最適化によるマニピュレータの視覚的運動学キャリブレーション

A Visual Kinematics Calibration Method for Manipulator Based on Nonlinear Optimization

シェア:XThreadsFacebookLINEはてブBluesky

高価な3次元計測器を使わず、単眼カメラの画像上での誤差を目的関数として非線形最適化によりマニピュレータのD-H運動学パラメータを補正する手法を提案した。

著者: Peng Gang, Wang Zhihao, Yang Jin, Li Xinde

分類: cs.RO

原文アブストラクト

The traditional kinematic calibration method for manipulators requires precise three-dimensional measuring instruments to measure the end pose, which is not only expensive due to the high cost of the measuring instruments but also not applicable to all manipulators. Another calibration method uses a camera, but the system error caused by the camera's parameters affects the calibration accuracy of the kinematics of the robot arm. Therefore, this paper proposes a method for calibrating the geometric parameters of a kinematic model of a manipulator based on monocular vision. Firstly, the classic Denavit-Hartenberg(D-H) modeling method is used to establish the kinematic parameters of the manipulator. Secondly, nonlinear optimization and parameter compensation are performed. The three-dimensional positions of the feature points of the calibration plate under each manipulator attitude corresponding to the actual kinematic model and the classic D-H kinematic model are mapped into the pixel coordinate system, and the sum of Euclidean distance errors of the pixel coordinates of the two is used as the objective function to be optimized. The experimental results show that the pixel deviation of the end pose corresponding to the optimized D-H kinematic model proposed in this paper and the end pose corresponding to the actual kinematic model in the pixel coordinate system is 0.99 pixels. Compared with the 7.9 deviation pixels between the pixel coordinates calculated by the classic D-H kinematic model and the actual pixel coordinates, the deviation is reduced by nearly 7 pixels for an 87% reduction in error. Therefore, the proposed method can effectively avoid system errors caused by camera parameters in visual calibration, can improve the absolute positioning accuracy of the end of the robotic arm, and has good economy and universality.

関連論文

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  3. 3GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  4. 4NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  5. 5UC BerkeleyとNVIDIAの研究者、AIエージェントでロボット制御コードを仮想環境で改善研究・技術

PR・アフィリエイト広告

FRONTIER(GPU搭載BTOパソコン)

FRONTIER(GPU搭載BTOパソコン)の公式広告バナーFRONTIERでGPU搭載PCを見る ↗
PR本紙発行元 EmplifAI