日本フィジカルAI新聞

世界のフィジカルAIを、日本語で。

医療ロボティクスarXiv:2011.00099

リアルタイム超音波フィードバックのみによる管状構造の自律ロボットスクリーニング

Autonomous Robotic Screening of Tubular Structures based only on Real-Time Ultrasound Imaging Feedback

シェア:XThreadsFacebookLINEはてブBluesky

超音波画像のリアルタイムセグメンテーションと3D点群化により、血管などの管状構造の長軸と半径を推定し、プローブを自動で位置・姿勢制御するスクリーニング手法を提案した。

著者: Zhongliang Jiang, Zhenyu Li, Matthias Grimm, Mingchuan Zhou, Marco Esposito, Wolfgang Wein, Walter Stechele, Thomas Wendler, Nassir Navab

分類: cs.RO

原文アブストラクト

Ultrasound (US) imaging is widely employed for diagnosis and staging of peripheral vascular diseases (PVD), mainly due to its high availability and the fact it does not emit radiation. However, high inter-operator variability and a lack of repeatability of US image acquisition hinder the implementation of extensive screening programs. To address this challenge, we propose an end-to-end workflow for automatic robotic US screening of tubular structures using only the real-time US imaging feedback. We first train a U-Net for real-time segmentation of the vascular structure from cross-sectional US images. Then, we represent the detected vascular structure as a 3D point cloud and use it to estimate the longitudinal axis of the target tubular structure and its mean radius by solving a constrained non-linear optimization problem. Iterating the previous processes, the US probe is automatically aligned to the orientation normal to the target tubular tissue and adjusted online to center the tracked tissue based on the spatial calibration. The real-time segmentation result is evaluated both on a phantom and in-vivo on brachial arteries of volunteers. In addition, the whole process is validated both in simulation and physical phantoms. The mean absolute radius error and orientation error ($\pm$ SD) in the simulation are $1.16\pm0.1~mm$ and $2.7\pm3.3^{\circ}$, respectively. On a gel phantom, these errors are $1.95\pm2.02~mm$ and $3.3\pm2.4^{\circ}$. This shows that the method is able to automatically screen tubular tissues with an optimal probe orientation (i.e. normal to the vessel) and at the same to accurately estimate the mean radius, both in real-time.

関連論文

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  3. 3newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  4. 4NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  5. 5UC BerkeleyとNVIDIAの研究者、AIエージェントでロボット制御コードを仮想環境で改善研究・技術

PR・アフィリエイト広告

OZ GAMING(GPU搭載BTOゲーミングPC)

OZ GAMING(GPU搭載BTOゲーミングPC)の公式広告バナーOZ GAMINGで完成品PCを見る ↗
PR本紙発行元 EmplifAI