内視鏡3D再構成arXiv:2012.11779

SERV-CT: 内視鏡3D再構成の検証用CTベース視差データセット

SERV-CT: A disparity dataset from CT for validation of endoscopic 3D reconstruction

シェア:XThreadsFacebookLINEはてブBluesky

ブタ全身死体を内視鏡で撮影しCTと位置合わせすることで、内視鏡ステレオ画像の参照視差・深度・オクルージョンを提供する検証データセットを構築した。

著者: P. J. "Eddie'' Edwards, Dimitris Psychogyios, Stefanie Speidel, Lena Maier-Hein, Danail Stoyanov

分類: cs.CV, cs.RO

原文アブストラクト

In computer vision, reference datasets have been highly successful in promoting algorithmic development in stereo reconstruction. Surgical scenes gives rise to specific problems, including the lack of clear corner features, highly specular surfaces and the presence of blood and smoke. Publicly available datasets have been produced using CT and either phantom images or biological tissue samples covering a relatively small region of the endoscope field-of-view. We present a stereo-endoscopic reconstruction validation dataset based on CT (SERV-CT). Two {\it ex vivo} small porcine full torso cadavers were placed within the view of the endoscope with both the endoscope and target anatomy visible in the CT scan. Orientation of the endoscope was manually aligned to the stereoscopic view. Reference disparities and occlusions were calculated for 8 stereo pairs from each sample. For the second sample an RGB surface was acquired to aid alignment of smooth, featureless surfaces. Repeated manual alignments showed an RMS disparity accuracy of ~2 pixels and a depth accuracy of ~2mm. The reference dataset includes endoscope image pairs with corresponding calibration, disparities, depths and occlusions covering the majority of the endoscopic image and a range of tissue types. Smooth specular surfaces and images with significant variation of depth are included. We assessed the performance of various stereo algorithms from online available repositories. There is a significant variation between algorithms, highlighting some of the challenges of surgical endoscopic images. The SERV-CT dataset provides an easy to use stereoscopic validation for surgical applications with smooth reference disparities and depths with coverage over the majority of the endoscopic images. This complements existing resources well and we hope will aid the development of surgical endoscopic anatomical reconstruction algorithms.

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  3. 3NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  4. 4GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  5. 5Google DeepMind、ロボット向けAIを発表新製品・発表

PR・アフィリエイト広告

OZ GAMING(GPU搭載BTOゲーミングPC)

OZ GAMING(GPU搭載BTOゲーミングPC)の公式広告バナーOZ GAMINGで完成品PCを見る ↗
PR本紙発行元 EmplifAI