手術器具の影が常に顕微鏡視野内に収まるようライトガイドの動きを自動制御し、ロボットの幾何情報と顕微鏡画像のみで網膜上の器具先端位置決めを実現した研究。

著者: Yuki Koyama, Murilo M. Marinho, Mamoru Mitsuishi, Kanako Harada

分類: cs.RO

原文アブストラクト

Vitreoretinal surgery is challenging even for expert surgeons owing to the delicate target tissues and the diminutive workspace in the retina. In addition to improved dexterity and accuracy, robot assistance allows for (partial) task automation. In this work, we propose a strategy to automate the motion of the light guide with respect to the surgical instrument. This automation allows the instrument's shadow to always be inside the microscopic view, which is an important cue for the accurate positioning of the instrument in the retina. We show simulations and experiments demonstrating that the proposed strategy is effective in a 700-point grid in the retina of a surgical phantom. Furthermore, we integrated the proposed strategy with image processing and succeeded in positioning the surgical instrument's tip in the retina, relying on only the robot's geometric information and microscopic images.