日本フィジカルAI新聞

世界のフィジカルAIを、日本語で。

外骨格arXiv:2110.00062

単関節・二関節外骨格の歩行時における多基準シミュレーション比較

Simulation-based multi-criteria comparison of mono-articular and bi-articular exoskeletons during walking with and without load

シェア:XThreadsFacebookLINEはてブBluesky

筋骨格モデルとパレート最適化を用い、荷重あり・なしの歩行で単関節・二関節外骨格の消費エネルギーと代謝コストを多基準比較した研究。

著者: Ali KhalilianMotamed Bonab, Volkan Patoglu

分類: cs.RO, cs.SY, eess.SY

原文アブストラクト

Developing exoskeletons that can reduce the metabolic cost of assisted subjects is challenging since a systematic design approach is required to capture the effects of device dynamics and the assistance torques on human performance. Design studies that rely on musculoskeletal models hold high promise in providing effective design guidelines, as the effect of various devices and different assistance torque profiles on metabolic cost can be studied systematically. In this paper, we present a simulation-based multi-criteria design approach to systematically study the effect of different device kinematics and corresponding optimal assistive torque profiles under actuator saturation on the metabolic cost, muscle activation, and joint reaction forces of subjects walking under different loading conditions. For the multi-criteria comparison of exoskeletons, we introduce a Pareto optimization approach to simultaneously optimize the exoskeleton power consumption and the human metabolic rate reduction during walking, under different loading conditions. We further superpose the effects of device inertia and electrical regeneration on the metabolic rate and power consumption, respectively. Our results explain the effects of heavy loads on the optimal assistance profiles of the exoskeletons and provide guidelines on choosing optimal device configurations under actuator torque limitations, device inertia, and regeneration effects. The multi-criteria comparison of devices indicates that despite the similar assistance levels of both devices, mono-articular exoskeletons show better performance on reducing the peak reaction forces, while the power consumption of bi-articular devices is less sensitive to the loading. Furthermore, for the bi-articular exoskeletons, the device inertia has lower detrimental effects on the metabolic cost of subjects and does not affect the Pareto-optimality of solutions.

関連論文

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  3. 3newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  4. 4NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  5. 5UC BerkeleyとNVIDIAの研究者、AIエージェントでロボット制御コードを仮想環境で改善研究・技術

PR・アフィリエイト広告

FRONTIER(GPU搭載BTOパソコン)

FRONTIER(GPU搭載BTOパソコン)の公式広告バナーFRONTIERでGPU搭載PCを見る ↗
PR本紙発行元 EmplifAI