日本フィジカルAI新聞

世界のフィジカルAIを、日本語で。

歩行arXiv:2112.05564

歩行の遊脚期における股関節・膝関節インピーダンスの同定

Identification of Hip and Knee Joint Impedance During the Swing Phase of Walking

シェア:XThreadsFacebookLINEはてブBluesky

遊脚中の脚に力を加える装置(LOPER)を開発し、非線形多体動力学モデルを用いて歩行中の股関節・膝関節インピーダンスを推定した研究。

著者: Herman van der Kooij, Simone S. Fricke, Ronald C. van 't Veld, Ander Vallinas Prieto, Arvid Q. L. Keemink, Alfred C. Schouten, Edwin H. F. van Asseldonk

分類: cs.RO, cs.SY, eess.SY

原文アブストラクト

Knowledge on joint impedance during walking in various conditions is relevant for clinical decision-making and the development of robotic gait trainers, leg prostheses, leg orthotics and wearable exoskeletons. Whereas ankle impedance during walking has been experimentally assessed, knee and hip joint impedance during walking have not been identified yet. Here we developed and evaluated a lower limb perturbator to identify hip, knee and ankle joint impedance during treadmill walking. The lower limb perturbator (LOPER) consists of an actuator connected to the thigh via rods. The LOPER allows to apply force perturbations to a free-hanging leg, while standing on the contralateral leg, with a bandwidth of up to 39 Hz. While walking in minimal impedance mode, the interaction forces between LOPER and the thigh were low (<5 N) and the effect on the walking pattern was smaller than the within-subject variability during normal walking. Using a non-linear multibody dynamical model of swing leg dynamics, the hip, knee and ankle joint impedance were estimated at three time points during the swing phase for nine subjects walking at a speed of 0.5 m/s. The identified model was well able to predict the experimental responses for the hip and knee, since the mean variance accounted (VAF) for was 99% and 96%, respectively. The ankle lacked a consistent response and the mean VAF of the model fit was only 77%, and therefore the estimated ankle impedance was not reliable. The averaged across-subjects stiffness varied between the three time points within 34-66 and 0-3.5 Nm/rad for the hip and knee joint respectively. The damping varied between 1.9-4.6 and 0.02-0.14 Nms/rad for hip and knee respectively. The developed LOPER has a negligible effect on the unperturbed walking pattern and allows to identify hip and knee impedance during the swing phase.

関連論文

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  3. 3NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  4. 4GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  5. 5UC BerkeleyとNVIDIAの研究者、AIエージェントでロボット制御コードを仮想環境で改善研究・技術

PR・アフィリエイト広告

OZ GAMING(GPU搭載BTOゲーミングPC)

OZ GAMING(GPU搭載BTOゲーミングPC)の公式広告バナーOZ GAMINGで完成品PCを見る ↗
PR本紙発行元 EmplifAI