医療ロボティクスarXiv:2204.00645

ゼロスラック分離型心腔内エコーカテーテルマニピュレータの設計と検証

Design and validation of zero-slack separable manipulator for Intracardiac Echocardiography

シェア:XThreadsFacebookLINEはてブBluesky

再利用可能なアクチュエータ部と使い捨てカテーテル部を分離し、腱を直接駆動することでバックラッシュを抑えた心腔内エコー用ロボットを設計し、モデル化と校正手法を提案・検証した論文。

著者: Christian DeBuy, Florin Ghesu, Reza Langari, Young-Ho Kim

分類: cs.RO

原文アブストラクト

Clinicians require substantial training and experience to become comfortable with steering Intracardiac echocardiography (ICE) catheter to localize and measure the area of treatment to watch for complications while device catheters are deployed in another access. Thus, it is reasonable that a robotic-assist system to hold and actively manipulate the ICE catheter could ease the workload of the physician. Existing commercially-available robotic systems and research prototypes all use existing commercially available ICE catheters based on multiple tendon-sheath mechanism (TSM). To motorize the existing TSM-based ICE catheter, the actuators interface with the outer handle knobs to manipulate four internal tendons. However, in practice, the actuators are located at a sterile, safe place far away from the ICE handle. Thus, to interface with knobs, there exist multiple coupled gear structures between two, leading to a highly nonlinear behavior (e.g. various slack, elasticity) alongside hysteresis phenomena in TSM. Since ICE catheters are designed for single use, the expensive actuators need to be located in a safe place so as to be reusable. Moreover, these actuators should interface as directly as possible with the tendons for accurate tip controls. In this paper, we introduce a separable ICE catheter robot with four tendon actuation: one part reusable and another disposable. Moreover, we propose a practical model and calibration method for our proposed mechanism so that four tendons are actuated simultaneously allowing for precise tip control and mitigating issues with conventional devices such as dead-zone and hysteresis with simple linear compensation. We consider an open-loop controller since many available ICE catheters are used without position-tracking sensors at the tip due to costs and single use

関連論文

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  3. 3GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  4. 4NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  5. 5UC BerkeleyとNVIDIAの研究者、AIエージェントでロボット制御コードを仮想環境で改善研究・技術

PR・アフィリエイト広告

MINISFORUM(ミニPC)

MINISFORUM(ミニPC)の公式広告バナーMINISFORUM公式ストアを見る ↗
PR本紙発行元 EmplifAI