経口手術用腱駆動関節ロボットユニットの準静的解析
Quasi-Static Analysis on Transoral Surgical Tendon-Driven Articulated Robot Units
経口手術用の腱駆動連続体ロボットにおいて、1つの連続体ユニットの回転角と圧力の関係を準静的に解析し、二分法で回転角を求めた。
著者: Hojin Seo, Yeoun-Jae Kim, Jaesoon Choi, Youngjin Moon
分類: cs.RO, physics.med-ph
原文アブストラクト
Wire actuation in tendon-driven continuum robots enables the transmission of force from a distance, but it is understood that tension control problems can arise when a pulley is used to actuate two cables in a push-pull mode. This paper analyzes the relationship between angle of rotation, pressure, as well as variables of a single continuum unit in a quasi-static equilibrium. The primary objective of the quasi-static analysis was to output pressure and the analysis, given the tensions applied. Static equilibrium condition was established, and the bisection method was carried out for the angle of rotation. The function for the bisection method considered pressure-induced forces, friction forces, and weight. {\theta} was 17.14{\deg}, and p was 405.6 Pa when Tl and Ts were given the values of 1 N and 2 N, respectively. The results seemed to be consistent with the preliminary design specification, calling for further simulations and experiments.