遠隔手術・アイトラッキングarXiv:2310.13720

遠隔ロボット手術におけるアイトラッキング:頭部装着型ソリューションの比較評価

Eye Tracking for Tele-robotic Surgery: A Comparative Evaluation of Head-worn Solutions

シェア:XThreadsFacebookLINEはてブBluesky

遠隔ロボット手術(da Vinci Research Kit)環境で頭部装着型アイトラッカー2機種(Tobii Pro 3 GlassesとPupil Labs Core)を比較し、瞳孔径と視線安定性を評価した。

著者: Regine Büter, Roger D. Soberanis-Mukul, Paola Ruiz Puentes, Ahmed Ghazi, Jie Ying Wu, Mathias Unberath

分類: cs.HC, cs.RO

原文アブストラクト

Purpose: Metrics derived from eye-gaze-tracking and pupillometry show promise for cognitive load assessment, potentially enhancing training and patient safety through user-specific feedback in tele-robotic surgery. However, current eye-tracking solutions' effectiveness in tele-robotic surgery is uncertain compared to everyday situations due to close-range interactions causing extreme pupil angles and occlusions. To assess the effectiveness of modern eye-gaze-tracking solutions in tele-robotic surgery, we compare the Tobii Pro 3 Glasses and Pupil Labs Core, evaluating their pupil diameter and gaze stability when integrated with the da Vinci Research Kit (dVRK). Methods: The study protocol includes a nine-point gaze calibration followed by pick-and-place task using the dVRK and is repeated three times. After a final calibration, users view a 3x3 grid of AprilTags, focusing on each marker for 10 seconds, to evaluate gaze stability across dVRK-screen positions with the L2-norm. Different gaze calibrations assess calibration's temporal deterioration due to head movements. Pupil diameter stability is evaluated using the FFT from the pupil diameter during the pick-and-place tasks. Users perform this routine with both head-worn eye-tracking systems. Results: Data collected from ten users indicate comparable pupil diameter stability. FFTs of pupil diameters show similar amplitudes in high-frequency components. Tobii Glasses show more temporal gaze stability compared to Pupil Labs, though both eye trackers yield a similar 4cm error in gaze estimation without an outdated calibration. Conclusion: Both eye trackers demonstrate similar stability of the pupil diameter and gaze, when the calibration is not outdated, indicating comparable eye-tracking and pupillometry performance in tele-robotic surgery settings.

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  3. 3newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  4. 4NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  5. 5UC BerkeleyとNVIDIAの研究者、AIエージェントでロボット制御コードを仮想環境で改善研究・技術

PR・アフィリエイト広告

MINISFORUM(ミニPC)

MINISFORUM(ミニPC)の公式広告バナーMINISFORUM公式ストアを見る ↗
PR本紙発行元 EmplifAI