協働ロボットアームを用いた発泡フォームの弾性計測
Elasticity Measurements of Expanded Foams using a Collaborative Robotic Arm
医療用ロボットによる触診や超音波検査を想定し、協働ロボットアームで種々の発泡フォームの弾性を計測して高精度機器による真値と比較評価した。
著者: Luca Beber, Edoardo Lamon, Luigi Palopoli, Luca Fambri, Matteo Saveriano, Daniele Fontanelli
分類: cs.RO
原文アブストラクト
Medical applications of robots are increasingly popular to objectivise and speed up the execution of several types of diagnostic and therapeutic interventions. Particularly important is a class of diagnostic activities that require physical contact between the robotic tool and the human body, such as palpation examinations and ultrasound scans. The practical application of these techniques can greatly benefit from an accurate estimation of the biomechanical properties of the patient's tissues. In this paper, we evaluate the accuracy and precision of a robotic device used for medical purposes in estimating the elastic parameters of different materials. The measurements are evaluated against a ground truth consisting of a set of expanded foam specimens with different elasticity that are characterised using a high-precision device. The experimental results in terms of precision are comparable with the ground truth and suggest future ambitious developments.
