日本フィジカルAI新聞

世界のフィジカルAIを、日本語で。

遠隔操作・手術ロボットarXiv:2407.13162

ロボットカテーテル手術のためのマスタ・フォロワ遠隔操作システム:設計、特性評価、追従制御

A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control

シェア:XThreadsFacebookLINEはてブBluesky

カテーテル手術用に3自由度のマスタ・フォロワ遠隔操作システムを開発し、把持・挿入・解放機構で座屈やねじれを防ぎつつ、円形・無限大・螺旋経路での追従精度を評価した。

著者: Ali A. Nazari, Jeremy Catania, Soroush Sadeghian, Amir Jalali, Houman Masnavi, Farrokh Janabi-Sharifi, Kourosh Zareinia

分類: cs.RO, cs.CV, cs.SY, eess.SY

原文アブストラクト

Minimally invasive robotic surgery has gained significant attention over the past two decades. Telerobotic systems, combined with robot-mediated minimally invasive techniques, have enabled surgeons and clinicians to mitigate radiation exposure for medical staff and extend medical services to remote and hard-to-reach areas. To enhance these services, teleoperated robotic surgery systems incorporating master and follower devices should offer transparency, enabling surgeons and clinicians to remotely experience a force interaction similar to the one the follower device experiences with patients' bodies. This paper presents the design and development of a three-degree-of-freedom master-follower teleoperated system for robotic catheterization. To resemble manual intervention by clinicians, the follower device features a grip-insert-release mechanism to eliminate catheter buckling and torsion during operation. The bidirectionally navigable ablation catheter is statically characterized for force-interactive medical interventions. The system's performance is evaluated through approaching and open-loop path tracking over typical circular, infinity-like, and spiral paths. Path tracking errors are presented as mean Euclidean error (MEE) and mean absolute error (MAE). The MEE ranges from 0.64 cm (infinity-like path) to 1.53 cm (spiral path). The MAE also ranges from 0.81 cm (infinity-like path) to 1.92 cm (spiral path). The results indicate that while the system's precision and accuracy with an open-loop controller meet the design targets, closed-loop controllers are necessary to address the catheter's hysteresis and dead zone, and system nonlinearities.

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  3. 3NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  4. 4GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  5. 5UC BerkeleyとNVIDIAの研究者、AIエージェントでロボット制御コードを仮想環境で改善研究・技術

PR・アフィリエイト広告

OZ GAMING(GPU搭載BTOゲーミングPC)

OZ GAMING(GPU搭載BTOゲーミングPC)の公式広告バナーOZ GAMINGで完成品PCを見る ↗
PR本紙発行元 EmplifAI