体積最適化空気圧アクチュエータを用いた2自由度ソフト肩エクソスーツの設計と評価
Design and Characterization of a Dual-DOF Soft Shoulder Exosuit with Volume-Optimized Pneumatic Actuator
体積を35.7%削減しつつトルクの94.2%を維持し応答速度を35.2%向上させた紡錘形角度アクチュエータを開発し、2自由度ソフト肩エクソスーツに統合して筋活動を最大63.7%低減できることを示した。
詳しい要約
1. どんなもの?
2. 先行研究と比べてどこがすごい?
3. 技術・手法の肝は?
4. どうやって有効だと検証した?
5. 議論はある?
6. 次に読むべき論文は?
※ AIが要旨から生成した要約です。正確性は原文をご確認ください。
著者: Rui Chen, Domenico Chiaradia, Daniele Leonardis, Antonio Frisoli
分類: cs.RO
原文アブストラクト
Portable pneumatic systems for 2 degree-of-freedom (DOF) soft shoulder exosuits remain underexplored, and face fundamental trade-offs between torque output and dynamic response that are further compounded by the need for multiple actuators to support complex shoulder movement. This work addresses these constraints through a volume-optimized spindle-shaped angled actuator (SSAA) geometry: by reducing actuator volume by 35.7% (357mL vs. 555mL), the SSAA maintains 94.2% of output torque while achieving 35.2% faster dynamic response compared to uniform cylindrical designs. Building on the SSAA, we develop a curved abduction actuator (CAA) based on the SSAA geometry and a horizontal adduction actuator (HAA) based on the pouch motor principle, integrating both into a dual-DOF textile-based shoulder exosuit (390 g). The exosuit delivers multi-modal assistance spanning shoulder abduction, flexion, and horizontal adduction, depending on the actuation. User studies with 10 healthy participants reveal that the exosuit substantially reduces electromyographic (EMG) activity across both shoulder abduction and flexion tasks. For abduction with HAA only, the exosuit achieved up to 59% muscle activity reduction across seven muscles. For flexion, both the single-actuator configuration (HAA only) and the dual-actuator configuration (HAA,+,CAA) reduced EMG activity by up to 63.7% compared to no assistance. However, the incremental benefit of adding the CAA to existing HAA support was limited in healthy users during flexion, with statistically significant additional reductions observed only in pectoralis major. These experimental findings characterize actuator contributions in healthy users and provide design guidance for multi-DOF exosuit systems.