日本フィジカルAI新聞

世界のフィジカルAIを、日本語で。

医療画像セグメンテーションarXiv:2404.07594

ロボット支援心血管カテーテル治療におけるツールセグメンテーションのための多方向デコーダ分岐による弱教師あり学習

Weakly-Supervised Learning via Multi-Lateral Decoder Branching for Tool Segmentation in Robot-Assisted Cardiovascular Catheterization

シェア:XThreadsFacebookLINEはてブBluesky

1つのエンコーダと複数の分岐デコーダを持つU-Netで擬似ラベルを生成し、部分注釈のみの血管造影データからカテーテル器具を高精度にセグメンテーションする弱教師あり手法を提案した。

著者: Olatunji Mumini Omisore, Toluwanimi Akinyemi, Anh Nguyen, Lei Wang

分類: cs.CV, cs.LG, cs.RO

原文アブストラクト

Robot-assisted catheterization has garnered a good attention for its potentials in treating cardiovascular diseases. However, advancing surgeon-robot collaboration still requires further research, particularly on task-specific automation. For instance, automated tool segmentation can assist surgeons in visualizing and tracking of endovascular tools during cardiac procedures. While learning-based models have demonstrated state-of-the-art segmentation performances, generating ground-truth labels for fully-supervised methods is both labor-intensive time consuming, and costly. In this study, we propose a weakly-supervised learning method with multi-lateral pseudo labeling for tool segmentation in cardiovascular angiogram datasets. The method utilizes a modified U-Net architecture featuring one encoder and multiple laterally branched decoders. The decoders generate diverse pseudo labels under different perturbations, augmenting available partial labels. The pseudo labels are self-generated using a mixed loss function with shared consistency across the decoders. The weakly-supervised model was trained end-to-end and validated using partially annotated angiogram data from three cardiovascular catheterization procedures. Validation results show that the model could perform closer to fully-supervised models. Also, the proposed weakly-supervised multi-lateral method outperforms three well known methods used for weakly-supervised learning, offering the highest segmentation performance across the three angiogram datasets. Furthermore, numerous ablation studies confirmed the model's consistent performance under different parameters. Finally, the model was applied for tool segmentation in a robot-assisted catheterization experiments. The model enhanced visualization with high connectivity indices for guidewire and catheter, and a mean processing time of 35 ms per frame.

関連論文

  1. 1Boston Dynamics、車輪付きAtlasの研究試作機を紹介研究・技術
  2. 2GXOとApptronik、Apolloの物流現場試験を拡大 最大1,000台の展開を構想量産・展開
  3. 3newmoとKDDIが資本業務提携 2028年に堺市で自動運転タクシー商用化目指す提携・買収
  4. 4NVIDIA、CoRLでGR00T 2とIsaac Lab 3.0を発表新製品・発表
  5. 5UC BerkeleyとNVIDIAの研究者、AIエージェントでロボット制御コードを仮想環境で改善研究・技術

PR・アフィリエイト広告

MINISFORUM(ミニPC)

MINISFORUM(ミニPC)の公式広告バナーMINISFORUM公式ストアを見る ↗
PR本紙発行元 EmplifAI