IMUと多体動力学モデルを密結合した運動・力学推定手法
A Tightly Coupled IMU-Based Motion Capture Approach for Estimating Multibody Kinematics and Kinetics
IMU計測と多体動力学モデルをIEKFで密結合し、磁気歪みやドリフトに強く運動学と動力学を同時推定する手法を提案。振り子とKukaロボットで検証した。
詳しい要約
1. どんなもの?
2. 先行研究と比べてどこがすごい?
3. 技術・手法の肝は?
4. どうやって有効だと検証した?
5. 議論はある?
6. 次に読むべき論文は?
※ AIが要旨から生成した要約です。正確性は原文をご確認ください。
著者: Hassan Osman, Daan de Kanter, Jelle Boelens, Manon Kok, Ajay Seth
分類: cs.RO, cs.SY, eess.SY
原文アブストラクト
Inertial Measurement Units (IMUs) enable portable, multibody motion capture (MoCap) in diverse environments beyond the laboratory, making them a practical choice for diagnosing mobility disorders and supporting rehabilitation in clinical or home settings. However, challenges associated with IMU measurements, including magnetic distortions and drift errors, complicate their broader use for MoCap. In this work, we propose a tightly coupled motion capture approach that directly integrates IMU measurements with multibody dynamic models via an Iterated Extended Kalman Filter (IEKF) to simultaneously estimate the system's kinematics and kinetics. By enforcing kinematic and kinetic properties and utilizing only accelerometer and gyroscope data, our method improves IMU-based state estimation accuracy. Our approach is designed to allow for incorporating additional sensor data, such as optical MoCap measurements and joint torque readings, to further enhance estimation accuracy. We validated our approach using highly accurate ground truth data from a 3 Degree of Freedom (DoF) pendulum and a 6 DoF Kuka robot. We demonstrate a maximum Root Mean Square Difference (RMSD) in the pendulum's computed joint angles of 3.75 degrees compared to optical MoCap Inverse Kinematics (IK), which serves as the gold standard in the absence of internal encoders. For the Kuka robot, we observe a maximum joint angle RMSD of 3.24 degrees compared to the Kuka's internal encoders, while the maximum joint angle RMSD of the optical MoCap IK compared to the encoders was 1.16 degrees. Additionally, we report a maximum joint torque RMSD of 2 Nm in the pendulum compared to optical MoCap Inverse Dynamics (ID), and 3.73 Nm in the Kuka robot relative to its internal torque sensors.
関連論文
- EgoWholeView:頭部搭載カメラのみによる身体と両手の動作キャプチャで身体性デモンストレーションを実現モーションキャプチャ
- 生体力学的知識を活用した多視点マーカーレス手の動きのモーションキャプチャモーションキャプチャ
- IMU-HOI: 接触を考慮した慣性融合による人間と物体の相互作用とモーションキャプチャの共生フレームワークモーションキャプチャ
- 単眼イベントカメラによるモーションキャプチャシステムモーションキャプチャ
- CoCap: 屋外環境における複数人物シーンの協調モーションキャプチャモーションキャプチャ
- HTC VIVE Ultimate Trackerの精度評価:ロボットと人間の動作を用いた多様な環境条件下での検証モーションキャプチャ